CFLFJ - 3100424-501;B4044015(WAS84009009) NICAD BATT,RECHARGEABLE
- MSDS: CFLFJ
- Manufacturer: RACAL COMMUNICATIONS INC
- Product Name: 3100424-501;B4044015(WAS84009009) NICAD BATT,RECHARGEABLE
- National Stock Number: 6140-01-251-8652
Product Identification
Product ID:3100424-501;B4044015(WAS84009009) NICAD BATT,RECHARGEABLE
MSDS Date:10/06/1996
FSC:6140
NIIN:01-251-8652
MSDS Number: CFLFJ
Responsible Party
ROCKVILLE, MD 20850-3213
US
Emergency Phone: 301-948-4420
Info Phone: 301-948-4420
Cage: 23386
Contractor
Telephone: 301-948-4420
Cage: 23386
Ingredients
NICKEL (SARA 313) (CERCLA) (20-30% AS NI) INCLUDES INGRED
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: 20-30%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9596
NICKEL HYDROXIDE (SARA 313) (CERCLA)
CAS: 12054-48-7
RTECS: QR7040000
Fraction By Weight: SEE #1%
OSHA PEL 1 MG(NI)/M3
ACGIH TLV: 0.1 MG(NI)/M3; 9596
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CADMIUM (SARA 313) (CERCLA) (13-15% AS CA) INCLUDES INGRED
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: 13-15%
OSHA PEL 0.2 MG/M3 DUST; Z-2
ACGIH TLV: 0.01 MG/M3 DUST;9596
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CADMIUM HYDROXIDE
CAS: 21041-95-2
Fraction By Weight: SEE #3%
OSHA PEL 0.05 MG CD/M3
ACGIH TLV: 0.05 MG CD/M3
COBALT (SARA 313) (1-2% AS CO) INCLUDE INGRED 6.
CAS: 7440-48-4
RTECS: GF8750000
Fraction By Weight: 1-2%
OSHA PEL 0.1 MG/M3
ACGIH TLV: 0.02 MG/M3; A3; 9596
COBALT HYDROXIDE
CAS: 1307-86-4
RTECS: GG0904000
Fraction By Weight: SEE #5%
OSHA PEL 0.05 MG/M3(COBALT)
ACGIH TLV: 0.1 MG/M3
POTASSIUM HYDROXIDE (CERCLA) (2-4% AS DRY KOH)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 2-4%
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ELECTROLYTE (KOH)IS CAUSTIC, CONTACT
W/SKIN OR EYES MAY CAUSE IRRIT.
Explanation of Carcinogenicity:PER
MSDS:CARCINOGENICITY:NTP/IARC/OSHA:NO.
First Aid
First Aid:IF LIQUID FROM LEAKER COMES IN CONTACT W/SKIN, REMOVE IMMED
W/WATER.FOR EYE CONTACT FLUSH W/RUNNING WATER FOR @LEAST 15MINS AND
CONTACT PHYSICIAN.
Fire Fighting
Flash Point:NA
Autoignition Temp:Autoignition Temp Text:NA
Lower Limits:NA
Upper Limits:NA
Unusual Fire/Explosion Hazard:MAY BURST WHEN SUBJ TO EXTREME
HEAT.CADMIUM FUMES MAY BE RELEASE DURING BURNING.
Accidental Release
Spill Release Procedures:AVOID SKIN AND EYE CONTACT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT ELECTRICALLY SHORT CIRCUIT, USE
PROPER BATTERY CHARGER.
Other Precautions:AVOID INCINERATION OR MUTILATION.
Exposure Controls
Supplemental Safety and Health
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NP
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:NA
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NA
Solubility in Water:NA
Appearance and Odor:5 CYLINDRICAL NICAD BATT CELLS INSIDE
CASE,7.6"LX1.0"DIA,MAX WT=5LBS.
Percent Volatiles by Volume:NP
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:IN ACCORDANCE WITH LCO STATE AND FEDERAL
REGULATIONS, USUALLY MAY BE DISPOSED OF IN SECURED LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.